Product

Water Quality Monitoring Station with Wireless Telemetry

A monitoring system designed for water-quality observation with wireless telemetry for remote data transmission and monitoring.
The Water Quality Monitoring Station with Wireless Telemetry is designed for monitoring important water-quality parameters using multiple sensors and a hand-held reader. The system supports dissolved oxygen, pH, ORP, conductivity and temperature measurements. It provides a compact solution for collecting water-quality data and can be configured for wireless telemetry applications.

Overview

The Water Quality Monitoring Station with Wireless Telemetry is designed
for monitoring multiple water-quality parameters using a combination of
sensors and a hand-held reader.

The system supports measurement of dissolved oxygen, pH, ORP, conductivity
and temperature. The multi-parameter arrangement provides researchers
with a convenient solution for collecting and monitoring water-quality
information.

System Components

  1. Hand-Held Reader:
    Used to receive and display the measurements obtained from the connected
    water-quality sensors.
  2. Dissolved Oxygen Sensor:
    Used for measuring dissolved oxygen in water.
  3. ORP Sensor:
    Used for measuring oxidation-reduction potential.
  4. Conductivity with Temperature Sensor:
    Used for conductivity measurement together with temperature measurement.

Key Features

  • Multi-parameter water-quality monitoring
  • Dissolved oxygen measurement
  • pH measurement
  • ORP measurement
  • Conductivity measurement
  • Temperature measurement
  • Hand-held reader
  • Wireless telemetry capability
  • Compact sensor arrangement
  • Suitable for water-quality monitoring applications

Water Quality Parameters

The monitoring system is designed to collect information from several
important water-quality parameters. The brochure identifies dissolved
oxygen, pH, ORP, conductivity and temperature as measurement parameters.

Dissolved Oxygen Measurement

The dissolved oxygen sensor is used to measure the concentration of
dissolved oxygen in the water. Dissolved oxygen measurements can be
used as an important parameter for evaluating water quality.

pH Measurement

The system supports pH measurement. The specified pH measurement range
is 0 to 14 pH, with a sodium-ion error occurring when the pH is above
12.3.

ORP Measurement

The ORP sensor is used for measuring oxidation-reduction potential.
The specified ORP measurement range is +/- 2000 mV.

Conductivity and Temperature Measurement

The conductivity with temperature sensor provides conductivity and
temperature measurement capabilities as part of the water-quality
monitoring system.

Hand-Held Reader

The system includes a hand-held reader for receiving and monitoring
measurements from the connected sensors. The reader provides a portable
interface for water-quality measurement applications.

Wireless Telemetry

The system is designed for wireless telemetry applications, allowing
water-quality monitoring systems to be configured for remote data
collection and transmission.

Sensor Configuration

The system is shown with separate sensors for dissolved oxygen, ORP,
and conductivity with temperature. These sensors can be used together
to provide multiple water-quality measurements.

Applications

  • Water-quality monitoring
  • Environmental water monitoring
  • Multi-parameter water analysis
  • Remote water-quality monitoring
  • Field water-quality measurements
  • Water-quality research

Measurement Range

The system supports a pH range of 0 to 14 pH and an ORP range of
+/- 2000 mV. Temperature measurements can be made from 0 to 100°C
(32 to 212°F). The maximum pressure specified for the sensor system
is 100 psi.

Cable Configuration

The specified cable length/connector configuration is 3 metres.

Monitor up to 32 sensor channels simultaneously, with real-time recording, graphical monitoring and wave-data analysis from a single system.

Technical Specifications

pH Measurement Range
0–14 pH
pH Condition
Sodium ion error when pH > 12.3
ORP Measurement Range
±2000 mV
Temperature Range
0–100°C (32–212°F)
Maximum Pressure
100 psi
Cable Length / Connector
3 m
Sensors Shown
Dissolved Oxygen, ORP, Conductivity with Temperature
Case Studies

Engineering in action.

Munambam–Alappuzha Tidal Study

10 Stations
2 Parameters
Coastal Study

Manimalayar River Hydrodynamic Monitoring System

4 Parameters
River Study
Thiruvalla

ONGC Underwater Measurement System

10 Channels
30m & 60m
5 Parameters

Bay of Bengal Ocean Thermal Wave Study

120 Metres
Multi-Channel